Ratings
| Type | Ratings | Primary | Secondary | BIL | Construction |
|---|---|---|---|---|---|
| Single-phase conventional | 10 to 167 kVA | 7200/12470Y V, 7620/13200Y V, 14400/24940GrdY V | 120/240 V, 240/480 V | 95 kV (125 kV at 24.9 kV) | One or two high-voltage bushings, cover-mounted; mineral oil |
| Single-phase CSP | 10 to 100 kVA | Same as conventional | 120/240 V | 95 kV | Internal secondary breaker and primary fuse link; surge arrester option |
| Three-phase overhead | On request | 15 kV class | 208Y/120 V, 480Y/277 V | 95 kV | Platform-mounted; quoted case by case |
- Mounting hardware, lifting lugs and nameplate per IEEE C57.12.20 and the buyer's standard.
- Amorphous-core and low-loss designs quoted where the evaluation formula rewards them.
What arrives with the quote.
Every quote for this product line includes the documents below, so your engineer can approve before anything is built.
- DOE efficiency certificationCertificate of compliance and DOE database listing for each model offered.
- Per-unit test reportFactory test report per IEEE C57.12.90: ratio, polarity, resistance, no-load and load losses, impedance, applied and induced voltage.
- Guaranteed lossesNo-load and load losses stated per model so the buyer can run its total-ownership-cost evaluation.
- Outline and nameplate drawingsDimensional drawing, weights, fluid volume and nameplate data for approval before manufacture.
- Country-of-origin statementOrigin of the unit and of its core, windings, tank and bushings.
- Warranty termsStated in each quote and administered in the United States.
Send ratings, quantities and a delivery point.
We reply within one business day with price, lead time and the documents above. Attach your material standard if you have one.
Other product lines
Launch line
Pad-mounted distribution transformers
Dead-front, compartmental, liquid-filled units for underground distribution. Single-phase for residential loops; three-phase for commercial, institutional and industrial service.
Ratings and standards →Phase two
Medium-voltage switchgear
Pad-mounted, air-insulated, dead-front sectionalizing and fused switchgear for underground loops. Quoted against the buyer's one-line and material standard.
Ratings and standards →Larger units
Substation and power transformers
Liquid-filled substation transformers from 2,500 kVA to 30 MVA and power transformers from 10 to 300 MVA, 69 to 345 kV class, including generator step-up units and autotransformers. Quoted with manufacturers that have plants in the United States and Canada, with factory acceptance testing and field service through our service partner.
Ratings and standards →