Liquid-filled substation transformers from 2,500 kVA to 30 MVA and power transformers from 10 to 300 MVA, 69 to 345 kV class, including generator step-up units and autotransformers. Quoted with manufacturers that have plants in the United States and Canada, with factory acceptance testing and field service through our service partner.

  • IEEE C57.12.00
  • IEEE C57.12.10
  • IEEE C57.12.90
  • IEEE C57.91 (loading)
  • IEEE C57.104 (DGA)
  • IEEE C57.131 (LTC)
  • NEMA TR 1 (sound)

Ratings

TypeRatingsHigh voltageLow voltageBILConstruction
Substation2,500 kVA to 30 MVA15 to 46 kV class (12.47 to 34.5 kV)2.4 to 34.5 kV95 to 250 kVONAN / ONAF, DETC, LTC on request, mineral oil or natural ester, skid or pad
Power, GSU and autotransformer10 to 300 MVA69 to 345 kV class4.16 to 138 kV350 to 1,175 kVONAN / ONAF / OFAF, LTC and DETC, bushing CTs, monitoring, conservator or sealed
Mobile substation5 to 60 MVA69 to 230 kV class4.16 to 34.5 kV350 to 900 kVTrailer-mounted with switchgear and protection, quoted per project
  • Market lead times for power transformers run 100 to 200 weeks in 2026; we quote delivery dates from the factory slot, not from a catalog.
  • DOE 10 CFR 431 does not cover units above 2,500 kVA; losses are guaranteed per unit and evaluated with the buyer's A and B factors.
  • Buy American, Build America Buy America and country-of-origin requirements are confirmed with the manufacturer before we quote, and documented in the submittal.
  • Field service, commissioning tests, oil processing and dissolved-gas analysis are available through our service partner; transport and rigging are quoted per site.
SUBMITTAL PACKAGE

What arrives with the quote.

Every quote for this product line includes the documents below, so your engineer can approve before anything is built.

  • DOE efficiency certificationCertificate of compliance and DOE database listing for each model offered.
  • Per-unit test reportFactory test report per IEEE C57.12.90: ratio, polarity, resistance, no-load and load losses, impedance, applied and induced voltage.
  • Guaranteed lossesNo-load and load losses stated per model so the buyer can run its total-ownership-cost evaluation.
  • Outline and nameplate drawingsDimensional drawing, weights, fluid volume and nameplate data for approval before manufacture.
  • Country-of-origin statementOrigin of the unit and of its core, windings, tank and bushings.
  • Warranty termsStated in each quote and administered in the United States.